Astrophotography diary

Observing session

A camera that kept stalling

The night of 21 to 22 October: the Moon between showers, a camera that kept stopping mid-frame, the motor focuser's first finer steps, and a polar alignment from 9.6° to 1.2° by turning the whole tripod. Rain twice; no pictures kept, but the camera fault was narrowed down to its USB 3 connection.

Polar alignment Focusing Hardware Weather

Shot 21 to 22 October, between 23:14 and 04:52, a back garden in Northern Ireland.

Between the showers

The Moon was out between breaks in the cloud. The tripod had been moved overnight, so the polar alignment had to be done again from scratch.

The scope started far out of focus. I brought it in by hand first, then the motor focuser took over. It was slow going, because the camera kept stopping in the middle of frames, timing out while waiting for the picture. Each time it had to be restarted. On M36 the focuser’s walk-in finally got the stars down to an HFR of 2.2, a bit better than usual. Then the rain came at 00:42.

After the rain

It cleared again at half three. Smaller focusing steps near the best point gave good focus quickly. The polar alignment then showed the mount had been knocked a long way in the rain: 9.6° from the pole and 16.5° west of north. Turning the whole tripod brought it to 1.2° in five rounds, close enough for 16-second frames.

An Andromeda patrol was started, but no 16-second frame ever arrived, and cloud closed in about five.

The camera fault

In the morning, with the cap on, we went through the camera fault properly. The kitchen socket, a different circuit upstairs and battery power all gave the same result: one-second frames worked, two seconds and longer never arrived. So it isn’t the mains. On the desktop, the same camera on USB 2 sent a 16-second frame where USB 3 sent nothing. The fault is in the camera’s USB 3 path. That went into the report for Altair.