Astrophotography diary

Build

How cold is cold enough?

Indoor tests on the 183M with the cap on: darks from +5 to -10 °C to test whether -5 °C is enough, the Moon video held at -5 °C, the power box switching the camera off and on by itself, and an attempt to make the cooler run away again.

Hardware telescopeyoke

telescopeyoke
v0.2.1, the latest release on this date

A rainy night and a cloudy day, so the camera stayed indoors with its cap on.

Is -5 °C enough?

Gary’s advice for the 183M is to cool it to -5 °C and no further. I wanted to know whether going colder would help. The test took six 120-second darks at each temperature, against 1-second frames for the zero level, and measured the dark signal, the noise and the hot pixels.

The first run went from +5 to -5 °C. The noise dropped from 7.3 to 6.3 ADU between +5 and 0 °C, then stopped falling. So I let one test go below the usual limit, down to -10 °C:

Sensor Dark signal Noise Hot pixels
-5.0 °C 0.020 ADU/s 6.71 ADU 1,613
-7.0 °C 0.031 ADU/s 6.66 ADU 1,387
-9.9 °C 0.030 ADU/s 6.60 ADU 1,051

Going from -5 to -10 °C lowered the noise by 1.6%. The dark signal is about 3 ADU in a two-minute frame at every temperature, too small to tell apart from its own scatter. There are a third fewer hot pixels, but the darks remove those anyway.

Gary was right: -5 °C is enough, and the camera stays there.

If you have a 183M or another IMX183 camera and are wondering the same thing, every number from both runs, plus the hot pixels and amp glow from 0.8 s to 300 s at -5 °C, is on TelescopeYoke’s results page, with the data file.

The Moon video, held cold

The Moon video had only ever been tested with the camera warm. This time the camera keeper held the sensor at -5 °C while three 2,400-frame videos ran through it, at 87, 86 and 85 frames a second with none dropped. Each video started by itself as the one before ended, then the camera warmed up slowly. That job is done.

The power box can switch USB after all

Svbony says the SV241’s ports are always on. Its USB ports aren’t: the laptop can switch each one off and on. The guide camera dropped off and came back, and so did the 183M, back at full USB 3 speed with a normal frame after. So if the camera ever jams on a night, the laptop can cut its power for eight seconds instead of me going out to pull the lead. The 12 V outputs really are always on.

Everything now runs from the box: the mount, the focuser on a lead I made this afternoon, and the camera’s cooler. That’s a lot less tape on the tube.

Trying to make the cooler run away

On 19 November the cooler ran away to -7.3 °C when its 12 V lead went in while it was switched on. Today I tried to make it happen again, with the set point only a few degrees below the room, so a runaway would show up long before anything got cold:

It didn’t run away either time, so it takes more than the lead going in with the cooler on. The camera’s controller had just been reset, and on 19 November that’s what cleared the fault. Since today, if the keeper ever catches a runaway, it cuts the camera’s USB power itself, which resets the controller, as well as switching the cooler off.